Operation Statistics Runtime · MTBF · MTTR
Operation Statistics
Real-time equipment runtime metrics, production line health, and system diagnostics
Fleet Running Hours
12,847
Last 30 days
Average Availability
94.2%
All equipment
Total Starts
847
Last 30 days
Mean Time Between Starts
858
Minutes
Real-Time Equipment Status
Pump-01
Running
Current Speed
1,847 RPM
Temperature
62.4°C
Last Update
2 min ago
Motor-02
Running
Current Speed
2,100 RPM
Temperature
58.9°C
Last Update
1 min ago
Fan-03
Stopped
Current Speed
0 RPM
Temperature
35.2°C
Last Update
14 min ago
Compressor-04
Running
Current Speed
1,650 RPM
Temperature
71.3°C
Last Update
3 min ago
Gearbox-05
Running
Current Speed
945 RPM
Temperature
52.8°C
Last Update
2 min ago
Conveyor-06
Running
Current Speed
120 RPM
Temperature
41.5°C
Last Update
1 min ago
284
days running
Status History
| Start Time | End Time | Running State | Duration (days) |
|---|---|---|---|
| 2024-10-15 08:30 | 2024-10-16 18:45 | Start up | 1.43 |
| 2024-10-16 18:45 | 2024-10-18 12:20 | Shut down | 1.73 |
| 2024-10-18 12:20 | 2024-10-22 06:15 | Start up | 3.75 |
| 2024-10-22 06:15 | 2024-10-23 14:30 | Shut down | 1.34 |
| 2024-10-23 14:30 | 2024-10-28 10:45 | Start up | 4.84 |
| 2024-10-28 10:45 | 2024-10-29 16:20 | Shut down | 1.23 |
| 2024-10-29 16:20 | 2024-11-02 09:00 | Start up | 3.69 |
| 2024-11-02 09:00 | 2024-11-03 11:15 | Shut down | 1.09 |
Production Lines Overview
Tower Equipment Line 1
8 equipment items
Health: 95%
Tower Equipment Line 2
6 equipment items
Health: 87%
Ground Equipment
12 equipment items
Health: 76%
Catenary Equipment
5 equipment items
Health: 92%
Mean Time Between Failures
284
Hours
Mean Time To Repair
3.2
Hours
Total Downtime
156
Hours (30d)
System Reliability
97.8%
This month
Equipment Comparison
| Equipment | Total Runtime (hrs) | Downtime (hrs) | Availability % | Starts | MTBF | MTTR |
|---|---|---|---|---|---|---|
| Pump-01 | 718.5 | 18.3 | 97.5% | 142 | 304 | 2.8 |
| Motor-02 | 692.4 | 22.1 | 96.9% | 156 | 271 | 3.1 |
| Fan-03 | 645.8 | 34.2 | 94.9% | 128 | 251 | 3.9 |
| Compressor-04 | 756.2 | 16.7 | 97.8% | 134 | 318 | 2.5 |
| Gearbox-05 | 701.3 | 24.5 | 96.6% | 147 | 289 | 3.3 |
| Conveyor-06 | 683.7 | 28.1 | 96.0% | 164 | 265 | 3.6 |
| Type Name | Image | AI Device Model | Instances | Actions |
|---|---|---|---|---|
| Pump | 💧 |
Centrifugal Pump v2.1 | 4 | |
| Motor | ⚡ |
AC Motor 3-Phase | 6 | |
| Fan | 💨 |
Centrifugal Fan v1.8 | 3 | |
| Compressor | 🔧 |
Rotary Compressor | 2 | |
| Gearbox | ⚙ |
Helical Gearbox | 5 | |
| Conveyor | 📦 |
Belt Conveyor v3.0 | 7 | |
| Crusher | 💥 |
Impact Crusher | 2 |
Diagnostic Reports
| No. | Equipment | Conclusion | Severity | Analyst | Created | Last Modified | Actions |
|---|---|---|---|---|---|---|---|
| 001 | Pump-01 | Cavitation detected, recommend maintenance | Warning | John Smith | 2024-10-28 | 2024-10-29 | |
| 002 | Motor-02 | Normal operation, no issues detected | Normal | Sarah Johnson | 2024-10-25 | 2024-10-27 | |
| 003 | Fan-03 | Bearing wear detected, schedule replacement | Danger | Mike Chen | 2024-10-20 | 2024-10-22 | |
| 004 | Compressor-04 | Vibration levels within acceptable range | Normal | Emma Davis | 2024-10-18 | 2024-10-18 | |
| 005 | Gearbox-05 | Lubrication analysis required, monitor viscosity | Attention | Robert Wilson | 2024-10-15 | 2024-10-26 | |
| 006 | Conveyor-06 | Belt tension adjustment needed for optimal performance | Attention | Lisa Anderson | 2024-10-10 | 2024-10-24 | |
| 007 | Pump-01 | Seal replacement completed successfully | Normal | James Martin | 2024-10-05 | 2024-10-06 | |
| 008 | Motor-02 | Thermal imaging shows elevated temperature spot | Warning | Patricia Lee | 2024-10-01 | 2024-10-23 |
Intelligent Diagnosis
| Action Time | Action Type | Action Object | Action User | Description | Result |
|---|---|---|---|---|---|
| 2024-10-29 14:32:18 | Add | Equipment Model | John Smith | Added new equipment model: Pump-Type-A | Success |
| 2024-10-29 13:15:45 | Edit | Sensor Config | Sarah Johnson | Updated sensor calibration parameters for Pump-01 | Success |
| 2024-10-29 11:47:22 | Delete | Alert Rule | Mike Chen | Removed deprecated alert rule: High-Temp-Threshold-Old | Success |
| 2024-10-28 16:23:01 | Edit | User Account | System | Updated permissions for user: analyst_team | Success |
| 2024-10-28 10:56:34 | Add | Sensor Config | Emma Davis | Added 3 new temperature sensors to Ground Equipment line | Success |
| 2024-10-27 15:33:09 | Edit | Equipment Model | Robert Wilson | Updated AI model association for Gearbox type | Success |
| 2024-10-27 09:18:44 | Delete | Equipment Model | John Smith | Removed obsolete equipment model: Legacy-Motor-v1 | Success |
| 2024-10-26 14:05:27 | Add | Alert Rule | Lisa Anderson | Created new alert rule: Bearing-Wear-Detection | Success |