SCADA & Data Integration OPC DA/UA · Modbus
Total Data Points
12,847
Real-time measurements
Active Connections
3
OPC DA, OPC UA, Modbus
Data Throughput
1,246
points/minute
Connection Health
98.7%
Uptime (24h)

Data Throughput (Last 24 Hours)

Connection Health

OPC Data Access (DA) Connected

Endpoint: opcda://127.0.0.1:49320/Kepware.KEPServerEX.V6

Direction: Bidirectional

Points Exported: 4,521

Points Imported: 2,310

Last Update: 2 seconds ago

Uptime: 99.2% (24h)

OPC Unified Architecture (UA) Connected

Endpoint: opc.tcp://127.0.0.1:49320/Kepware

Direction: Bidirectional

Points Exported: 5,240

Points Imported: 1,896

Last Update: 1 second ago

Uptime: 98.9% (24h)

Modbus Protocol Connected

Slave Address: 127.0.0.1:502

Direction: Master/Slave

Points Exported: 3,086

Points Imported: 1,654

Last Update: 3 seconds ago

Uptime: 97.8% (24h)

OPC Data Access (DA) – Export

Connected
2 seconds ago

Exported Tags

Mars Measurement Point OPC Tag Path Value Quality Timestamp
Motor_A1.Vibration.Velocity Channel1.Device1.Motor_A1_Vibration 3.47 mm/s Good 2026-04-17 14:32:18
Motor_A1.Temperature Channel1.Device1.Motor_A1_Temp 62.3 °C Good 2026-04-17 14:32:17
Pump_B2.Flow.Rate Channel1.Device2.Pump_B2_Flow 245.6 L/min Good 2026-04-17 14:32:18
Compressor_C3.Pressure Channel1.Device3.Compressor_Pressure 8.2 bar Good 2026-04-17 14:32:16
Motor_A1.Current Channel1.Device1.Motor_A1_Current 12.5 A Uncertain 2026-04-17 14:32:14

OPC Data Access (DA) – Import

Imported Tags

OPC Tag Mars Equipment Data Type Status
Siemens.Motor.Speed Motor_D4 Int32 Active
Siemens.Sensor.Output Sensor_E5 Float32 Active

OPC Unified Architecture (UA) – Export

Exported Nodes

Mars Equipment OPC UA Node ID Current Value Data Type Timestamp
Motor_A1.Vibration.Velocity ns=2;i=102 3.47 Double 2026-04-17 14:32:18
Motor_A1.Temperature ns=2;i=103 62.3 Double 2026-04-17 14:32:17
Pump_B2.Flow.Rate ns=2;i=201 245.6 Double 2026-04-17 14:32:18
Compressor_C3.Pressure ns=2;i=301 8.2 Double 2026-04-17 14:32:16

OPC UA – Import

Current Certificate: Not configured

Imported Nodes

OPC UA Node ID Node Name Mars Equipment Status
ns=3;i=1001 Siemens_Motor_Speed Motor_D4 Active
ns=3;i=1002 Siemens_Sensor_Pressure Sensor_E5 Active

Modbus – Export (Slave Mode)

Register Mapping (Export)

Mars Measurement Point Register Type Address Data Type Current Value
Motor_A1.Vibration.Velocity Holding Register 100 Float32 3.47
Motor_A1.Temperature Holding Register 102 Int16 62
Pump_B2.Flow.Rate Input Register 200 Float32 245.6
Compressor_C3.Pressure Holding Register 300 Float32 8.2
Motor_A1.Current Input Register 104 Int16 12

Modbus – Import (Master Mode)

Connected Slave Devices

Device Name IP Address Unit ID Status Last Poll
PLC-Main-Line-1 192.168.1.50 1 Connected 1 second ago
VFD-Motor-Control 192.168.1.51 2 Connected 2 seconds ago
RTU-Sensor-Bank 192.168.1.52 3 Disconnected 45 seconds ago
Timestamp Protocol Direction Status Message
2026-04-17 14:32:18 OPC UA Export Success Updated 4 nodes successfully
2026-04-17 14:32:17 OPC DA Export Success Tag group 'Motor_A1' exported: 5 points
2026-04-17 14:32:16 Modbus Import Success Polled device PLC-Main-Line-1: 12 registers read
2026-04-17 14:30:45 Modbus Import Warning RTU-Sensor-Bank connection timeout, retrying...
2026-04-17 14:28:12 OPC UA Import Success Imported node ns=3;i=1001 → Motor_D4
2026-04-17 14:15:33 OPC DA Import Error Connection refused: server unreachable at opcda://192.168.1.200:49320
2026-04-17 14:00:00 OPC UA Export Success Subscription active: publishing interval 1000ms, queue size 10
2026-04-17 13:45:22 Modbus Import Warning High response time (234ms) from VFD-Motor-Control